Serial Port Data Logger Current

Posted on -

Download our latest data logger software here today. This device makes data logging easier then ever before.

Download RS-232 Data Logger for free. Allows you to redirect all communication data from RS232 compliant serial port device into a text file for further analysis. RS232 Data Logger redirects data from any available serial port/ports and works under Virtual Machine. Click on a station to see a summary of current data and click the bulletin to see the station’s customized weather dashboard. WeatherLink Cloud makes 4x the amount of data on your Data Logger (USB, Serial, WL IP) available to you for download. WeatherLink® Serial-Port Data Logger $ 165.00 (#6510SER).

Data Acquisition

The SITE-LOG LPV-1 is a 7-channel, battery powered, stand-alone voltage data logger, with storage up to 8 MB of data in non-volatile flash memory. Input voltage signals can be from sensors, transducers, transmitters or any other common voltage sources.Its on-board temperature channel provides environment monitoring and temperature compensation.Its aluminum enclosure makes it excellent in the harshest industrial environment.Plug & Play USB port and versatile custom equation simplify communications and engineering unit conversion. 16-bit ADC makes it well suited for science and laboratory applications where precise and accurate measurements are critical.Simply plug the logger to computer's USB port, and the software automatically recognizes it and handles the configuration, downloading, graph viewing and more. Features:. 16-bit analog-to-digital converter. Temperature Compensation. 8 megabyte memory size.

Both USB and serial interfaces with auto baud rate of up to 115200 bps. Programmable input ranges (2 VDC to 20 VDC). Over 10 years of battery life.

Powerful software for configuration, downloading, plotting, analysis and alarm reporting. Configurable alarm controls/excitation controls. Wide sampling interval selections (20 milliseconds to 12 hours). Rugged aluminum enclosure. Coated PCB to protect against moisture, corrosion and mildew.Documents. GeneralProduct NameSITE-LOG Voltage Data LoggerModelLPV-1InputsConnectionPlugable terminal block for seven external channels, excitation controls and alarm outputsChannelsOne on-board thermistor temperature (-40°C 70°C, -40°F 158°F)Seven external Voltage DC.

The CR1000 consists of a measurement and control module and a wiring panel. This data logger uses an external keyboard/display and power supply. Low power consumption allows the CR1000 to operate for extended time periods on a battery recharged with a solar panel—eliminating the need for AC power.

Data Logger Testo

The CR1000 suspends execution when primary power drops below 9.6 V, reducing the possibility of inaccurate measurements.The CR1000's module measures sensors, drives direct communications and telecommunications, reduces data, controls external devices, and stores data and programs in on-board, non-volatile storage. The electronics are RF shielded and glitch protected by the sealed, stainless-steel canister. A battery-backed clock assures accurate timekeeping. The module can simultaneously provide measurement and communication functions.

The on-board, BASIC-like programming language supports data processing and analysis routines.The CR1000WP is a black, anodized aluminum wiring panel that is compatible with all CR1000 modules. The wiring panel includes switchable 12 V, redistributed analog grounds (dispersed among analog channels rather than grouped), unpluggable terminal block for 12 V connections, gas-tube spark gaps, and 12 V supply on pin 8 to power our COM-series phone modems and other peripherals. The control module easily disconnects from the wiring panel allowing field replacement without rewiring the sensors.Originally, the standard CR1000 had 2 MB of data/program storage, and an optional version, the CR1000-4M, had 4 MB of memory. In September 2007, the standard CR1000 started having 4 MB of memory, making the CR1000-4M obsolete. Data loggers that have a module with a serial number greater than or equal to 11832 will have a 4 MB memory. The 4 MB data loggers will also have a sticker on the canister stating “4M Memory”. Software ProductCompatibleNoteVersion 3.0 or higherVersion 1.2 or higher(retired)Version 3.1 or higher(retired)Version 2.0 or higherVersion 1.0 or higherVersion 2.0 or higherAdditional Compatibility Information SensorsWith several channel types, the CR1000 is compatible with nearly every available sensor, including thermocouples, SDI-12 sensors, and 4 to 20 mA sensors (via a terminal input module, such as the ).

A custom ASIC chip expands its pulse count, control port, and serial communications capabilities. The CR1000's I/O ports can be paired as transmit and receive, allowing serial communications with serial sensors and devices. Measurement & Control PeripheralsThe CR1000 is compatible with all of our CDMs (requires an SC-CPI), SDMs, multiplexers, vibrating-wire interfaces, terminal input modules, and relays.

CommunicationsThe CR1000 communicates with a PC via direct connect, Ethernet interfaces, multidrop modems, short-haul modems, phone modems (land line, digital cellular, and voice-synthesized), RF telemetry, and satellite transmitters (Argos, Iridium, and Inmarsat).Data can be viewed on the CR1000KD Keyboard Display, the CD100 Mountable Display with Keyboard, an iOS or Android device (requires LoggerLink), CD295 DataView II Display, or a user-supplied PDA (PConnect or PConnectCE software required).Compatible external data storage devices are the CFM100, NL115, and SC115. EnclosuresThe CR1000 and its power supply can be housed in any of our standard enclosures.

PowerAny 12 Vdc source can power the CR1000 datalogger. Power supplies commonly used with the CR1000 are the BPALK, PS150, and PS200. The BPALK provides eight non-rechargeable D-cell alkaline batteries with a 7.5 Ah rating at 20°C.Both the PS150 and PS200 consist of a sealed rechargeable 7 Ah battery and a charging regulator. Their battery should be connected to a charging source (either a wall charger or solar panel). These two power supplies differ in their charging regulator. The PS150 has a standard regulator and the PS200 has a micro-controller-based smart regulator. The PS200's regulator provides two-step constant voltage charging and temperature compensation that optimize battery charging and increases the battery’s life.Also available are the BP12 and BP24 battery packs, which provide nominal ratings of 12 and 24 Ah, respectively.

Data

These batteries should be connected to a regulated charging source (e.g., a CH100 or CH200 connected to a unregulated solar panel or wall charger). SoftwareCRBasic, the CR1000's full programming language, supports simple or complex programming and many onboard data reduction processes. CR1000 OS v.32.03 (5.10 MB)Execution of this download installs the CR1000 Operating System and Compiler on your computer. It also updates the CR1000 support files for the CRBasic Editor.Note: This OS has crossed the 2 Meg CR1000 size limit for remote download. The OS must be downloaded to the 2 Meg CR1000 via direct connect with the Device Configuration Utility. All OS download methods are supported by the 4 Meg CR1000.Upgrading from versions prior to version 28 of the Operating System will reset the datalogger’s CPU drive.

This is due to a change in the format of the file system from FAT16 to FAT32. In order for the datalogger to operate correctly, as part of the upgrade, the CPU drive is formatted to FAT32. Any programs stored and running from the CPU drive will be lost. It is not recommended to update the datalogger’s Operating System over a remote connection where program control regulates the communication equipment (turning it on or off, etc.).

In these cases, an on-site visit and a backup using DevConfig’s backup utility is necessary to update the datalogger’s Operating System.In all cases where the datalogger is being updated from an Operating System prior to 28, the use of DevConfig’s backup utility is recommended due to the CPU drive being formatted using the new FAT32 format. The FileManage instruction can be used to hide files on a data logger.

The following are some important reminders:. Hidden files will not be displayed and therefore are not accessible via File Control, FTP, HTTP, etc. Hidden CR and DLD program files and those specified by the Include instruction can be used by the data logger. Hidden files can be accessed under program control using the FileOpen, FileRead, and FileWrite instructions. Hidden files can be further protected by encrypting them with the CRBasic Editor or the FileEncrypt instruction.